01 / Key features

Key features

  • Digital measurement
  • Method matched to the parameter
  • Repeatable results and data capture

02 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterPH-900P
pH — Range
-2.000~20.000pH
pH — Resolution
0.001, 0.01, 0.1pH, selectable
pH — Accuracy
±0.002pH
pH — Calibration Points
1 to 5 points
pH — pH Buffer Options
USA, NIST, DIN, 2 custom buffers
ORP(Optional)
Range · ±1999.9mV
ORP(Optional) (2)
Resolution · 0.1, 1mV, selectable
ORP(Optional) (3)
Accuracy · ±0.2mV
ORP(Optional) (4)
Calibration Points · 1 point
lon(Optional)
Range · 0.001~19999(depending on the range of ISE)
lon(Optional) (2)
Resolution · 0.001, 0.01, 0.1, 1
lon(Optional) (3)
Accuracy · ±0.5%F.S.(monovalent), ±1%F.S.(divalent)
lon(Optional) (4)
Measurement Units · ppm, mg/L, mol/L, mmol/L
lon(Optional) (5)
Calibration Points · 2 to 5 points(0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000)
Conductivity
Range · 0.1~2μS/cm(CON-0.1, optional) 2~20mS/cm(CON-1.standard) 20~200mS/cm(CON-10, optional)
Conductivity (2)
Resolution · 0.001, 0.01, 0.1, 1
Conductivity (3)
Accuracy · ±0.5%F.S.
Conductivity (4)
Calibration Points · 1 to 5 points
Conductivity (5)
Calibration Solutions · 10μS/cm, 84μS/cm, 1413μS/cm, 12.88mS/cm, 111.8mS/cm
Conductivity (6)
T emperature Coefficient · Linear(0.0~10.0%/°C), pure water
Conductivity (7)
Reference Temperature · 20/25°C
Conductivity (8)
Cell Constant · K=0.1, 1, 10 or custom
TDS
Range · 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt
TDS (2)
Resolution · 0.01, 0.1, 1
TDS (3)
Accuracy · ±1%F.S.
TDS (4)
TDS Factor · 0.1~1.0(default 0.5)
Salinity
Range · 0.00~42.00psu, 0.00~80.00ppt
Salinity (2)
Resolution · 0.01
Salinity (3)
Accuracy · ±1%F.S.
Resistivity
Range · 0.00~20.00MΩ
Resistivity (2)
Resolution · 0.01
Resistivity (3)
Accuracy · ±1%F.S.
DO
Range · 0.00~20.00mg/L, 0.0~200.0% saturation
DO (2)
Resolution · 0.01mg/L, 0.1%
DO (3)
Accuracy · ±0.2mg/L, ±2.0%
DO (4)
Calibration Points · 1 or 2 points
DO (5)
Barometric Pressure Correction · 60.0~112.5kPa/450~850mmHg, manual
DO (6)
Salinity Correction · 0.0~50.0g/L, manual
Other Specifications
Temperature Compensation · 0~100°C/32~212°F, manual or automatic
Other Specifications (2)
Memory · 500 data sets. USB communication interface
Other Specifications (3)
Power Requirements · 3*1.5V AA batteries or DC5V power adapter
Other Specifications (4)
Dimension · 170*85*30mm
Other Specifications (5)
Net Weight · 300g
Other Specifications (6)
Packing Size · 450*320*100mm
Other Specifications (7)
Gross Weight · 2kg