Laboratory analysis
Digital Viscometer BDV-S BDV-N Series
BDV-1S / BDV-9S / BDV-5S / BDV-8S / BDV-1N / BDV-2N / BDV-3N / BDV-4N
Instrumental measurement of physicochemical parameters for laboratory workflows.
Made to orderPrice on request
- Manufacturer
- BIOBASE
Reply within 24 hoursValidated selection and configurationDelivery across mainland Portugal, Madeira, the Azores, and all European countries.
01 / Key features
Key features
- Digital measurement
- Method matched to the parameter
- Repeatable results and data capture
02 / LaboratoriX technical datasheet
LaboratoriX technical datasheet
Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.
| Parameter | BDV-1S | BDV-9S | BDV-5S | BDV-8S | BDV-1N | BDV-2N | BDV-3N | BDV-4N |
|---|---|---|---|---|---|---|---|---|
| Measured Range(mPa.s) | 1~100,000 | 1~6,000,000 | 20~100,000 | 20~2,000,000 | 20~600,000 | 12~6,000,000 | 160~80,000,000 | 50~10,000,000 |
| Rotation Speed(rpm) | 6, 12, 30, 60 | 0.1, 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 | 6, 12, 30, 60 | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 | 1~60 | 0.1~99.9 | 0.1~99.9 | 0.1~200 |
| Number of Spindle | 4 types(L1~L4) | 4 types(L1~L4) | 4 types(L1~L4) | 4 types(L1~L4) | 4 types(L1~L4) | 4 types(L1~L4) | 4 types(L1~L4) | 4 types(21.27.28.29) |
| Measurement Accuracy | ±5%(FS)(Newtonian Fluid) | ±3(FS)(Newtonian Fluid) | ±1%(FS)(Newtonian Fluid) | ±1%(FS)(Newtonian Fluid) | ±1%(FS)(Newtonian Fluid) | ±1%(FS)(Newtonian Fluid) | ±1%(FS)(Newtonian Fluid) | ±1%(FS)(Newtonian Fluid) |
| Repeatability | ||||||||
| Power Supply | ||||||||
| Standard Accessory | / | / | RS232 standard output interface | RS232 standard output interface | RTD temperature probe RS232 standard output interface | RTD temperature probe RS232 standard output interface | RTD temperature probe RS232 standard output interface | RTD temperature probe RS232 standard output interface |
| Optional Accessory | / | RTD temperature probe | RTD temperature probe, Specially used printer | RTD temperature probe, Specially used printer | Specially used printer | Specially used printer | Specially used printer | Specially used printer |
| LO Spindle is for Option Measured Range(mPa.s) | 1~10 | 1~10 | 1~100 | 1~2000 | 1~600 | 0.6~6000 | 6~6000 | 3~6000 |
| Package Size(W*D*H) | 460*390*230mm | 460*390*230mm | 400*350*360mm | 400*350*360mm | 400*350*360mm | 400*350*360mm | 400*350*360mm | 400*350*550mm |
| Gross Weight | 7.5kg | 7.5kg | 9kg | 9kg | 9kg | 9kg | 9kg | 10.5kg |
MADE-TO-ORDER SUPPLY
Do you need this equipment?
Share the application, configuration, quantity and delivery location. We prepare a tailored proposal with the required documentation.






