Laboratory analysis

Benchtop Multiparameter Water Quality Meter M300F

M300F

Instrumental measurement of physicochemical parameters for laboratory workflows.

Made to orderPrice on request
Manufacturer
BIOBASE
Request a quote
Reply within 24 hoursValidated selection and configurationDelivery across mainland Portugal, Madeira, the Azores, and all European countries.

01 / Key features

Key features

  • Digital measurement
  • Method matched to the parameter
  • Repeatable results and data capture

02 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterM300F
pH — Range
-2.00~20.00pH
pH — Resolution
0.1, 0.01pH
pH — Accuracy
±0.01pH
pH — Calibration Points
1~5 points
pH — Standard Customization
Yes
pH — Standard Recognition
NIST, GB, USA and DIN buffers
pH — Slope Limit
Yes
mV(ORP probe optional) — Range
-2000.0~2000.0mV
mV(ORP probe optional) — Resolution
0.1mV
mV(ORP probe optional) — Accuracy
±0.3mV or ±0.1%
pX
Range · -2.00~20.00pX
pX (2)
Resolution · 0.1, 0.01pX
pX (3)
Accuracy · ±0.01pX
pX (4)
Calibration Points · 1~5 points
ISE(Optional)
Range · 1.000e-9~9.999e+9
ISE(Optional) (2)
Resolution · Up to 4 significant digits
ISE(Optional) (3)
Accuracy · ±0.5%
ISE(Optional) (4)
Calibration Points · 1~5 points
ISE(Optional) (5)
Unit · mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb
Conductivity
Range · 0.000μS/cm~1000mS/cm
Conductivity (2)
Resolution · 0.001μS/cm minimum, various with range selection
Conductivity (3)
Accuracy · ±1.0%FS
Conductivity (4)
Calibration Points · 1~3 points
Conductivity (5)
Standard Recognition · 84μS/cm, 1413μS/cm, 12.88mS/cm
Conductivity (6)
Reference Temperature · 20, 25ºC
Resistivity
Range · 5.00~20.00MΩ·cm
Resistivity (2)
Resolution · 0.01Ω·cm minimum
Resistivity (3)
Accuracy · ±1.0%FS
TDS
Range · 0.00ppm~300ppt
TDS (2)
Resolution · 0.01mg/L minimum, various with range selection
TDS (3)
Accuracy · ±1.0%FS
Salinity
Range · 0.0~80.0ppt
Salinity (2)
Resolution · 0.1ppt
Salinity (3)
Accuracy · ±2ppt
DO Concentration-Polarographic
Range · 0.00~20.00ppm
DO Concentration-Polarographic (2)
Resolution · 0.01ppm
DO Concentration-Polarographic (3)
Accuracy · ±0.10ppm
DO Concentration-Polarographic (4)
Calibration Points · Air-saturated water or zero point
DO Concentration-Polarographic (5)
Barometric Compensation · Yes
DO Concentration-Polarographic (6)
Manual Salinity Factor Correction · Yes
% Saturation -Polarographic
Range · 0.0~200.0%
% Saturation -Polarographic (2)
Resolution · 0.1%
% Saturation -Polarographic (3)
Accuracy · ±2.0%
Temperature — Range
-5~110ºC/23~230ºF
Temperature — Resolution
0.1
Temperature — Accuracy
±0.2
Measurement
Reading Mode · Auto read(Fast, medium, slow), timed, continuous
Measurement (2)
Reading Prompts · Reading, stable, locked
Measurement (3)
Temp. Compensation · ATC, MTC
Data Management — Data Storage
500 results each
Data Management — GLP Features
Yes
Outputs
USB · PC
Outputs (2)
RS232 · Printer
Power Supply
AC adapter, 100~240V, 50/60Hz AC input, DC9V output
External Size(W*D*H)
242*195*68mm
Package Size(W*D*H)
370*305*330mm
Net Weight
0.9kg
Gross Weight
3.5kg

MADE-TO-ORDER SUPPLY