Home/Catalogue/PH-PC100 / PH-CD100 / PH-PD100

Laboratory analysis

Benchtop Multiparameter Meter PH-PC100 PH-CD100 PH-PD100

PH-PC100 / PH-CD100 / PH-PD100

Instrumental measurement of physicochemical parameters for laboratory workflows.

Made to orderPrice on request
Manufacturer
BIOBASE
Request a quote
Reply within 24 hoursValidated selection and configurationDelivery across mainland Portugal, Madeira, the Azores, and all European countries.

01 / Key features

Key features

  • Digital measurement
  • Method matched to the parameter
  • Repeatable results and data capture

02 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterPH-PC100PH-CD100PH-PD100
pH — Range-2.000~20.000pH/-2.000~20.000pH
pH — Resolution0.01/0.1pH/0.01/0.1pH
pH — Accuracy±0.01pH±one digit/±0.01pH±one digit
mV(ORP probe optional) — Range-1999mV~1999mV/-1999mV~1999mV
mV(ORP probe optional) — Resolution1mV/1mV
mV(ORP probe optional) — Accuracy±0.1%FS±one digit/±0.1%FS±one digit
Conductivity
Common to all modelsRange · 0~200.0mS/cm(Auto divided: 0~19.99μS/cm; 20.0~199.9μS/cm; 200~1999μS/cm; 2.00~19.99mS/cm; 20.00~199.9mS/cm) · 0~200.0mS/cm(Auto divided: 0~19.99μS/cm; 20.0~199.9μS/cm; 200~1999μS/cm; 2.00~19.99mS/cm; 20.00~199.9mS/cm) · /
Conductivity (2)
Common to all modelsResolution · 0.001 · 0.001 · /
Conductivity (3)
Common to all modelsAccuracy · ±1.0%FS±one digit · ±1.0%FS±one digit · /
Conductivity (4)
Common to all modelsATC Range · 0~50℃ · 0~50℃ · /
TDS
Common to all modelsRange · 0~100.0g/L · 0~100.0g/L · /
TDS (2)
Common to all modelsResolution · 0.001 · 0.001 · /
TDS (3)
Common to all modelsAccuracy · ±1.0%FS±one digit · ±1.0%FS±one digit · /
TDS (4)
Common to all modelsATC Range · 0~50℃ · 0~50℃ · /
Resistivity
Common to all modelsRange · 5.00~100.0MΩ·cm · 5.00~100.0MΩ·cm · /
Resistivity (2)
Common to all modelsResolution · 0.001 · 0.001 · /
Resistivity (3)
Common to all modelsAccuracy · ±1.0%FS±one digit · ±1.0%FS±one digit · /
Resistivity (4)
Common to all modelsATC Range · 0~50℃ · 0~50℃ · /
Salinity
Common to all modelsRange · 0~100.0ppt · 0~100.0ppt · /
Salinity (2)
Common to all modelsResolution · 0.1 · 0.1 · /
Salinity (3)
Common to all modelsAccuracy · ±1.0%FS±one digit · ±1.0%FS±one digit · /
Salinity (4)
Common to all modelsATC Range · 0~50℃ · 0~50℃ · /
DO
Common to all modelsRange · / · 0~20.00mg/L, 0~200.0 % · 0~20.00mg/L, 0~200.0 %
DO (2)
Common to all modelsResolution · / · 0.01mg/L · 0.01mg/L
DO (3)
Common to all modelsAccuracy · / · ±0.30mg/L · ±0.30mg/L
DO (4)
Common to all modelsATC Range · / · 0~50℃, automatically · 0~50℃, automatically
DO (5)
Common to all modelsSalinity Compensation · / · 0~45ppt, manual · 0~45ppt, manual
DO (6)
Common to all modelsBarometric Compensation · / · 0~200kPa, automatically · 0~200kPa, automatically
Temperature — Range
Common to all models-9.9~130.0℃/14.1~266.0℉
Temperature — Resolution
Common to all models0.1℃
Temperature — Accuracy
Common to all models±0.2℃
Data Storage
Common to all models450 groups
Data Transfer
Common to all modelsUSB stick Bluetooth connection to printer(Optional)
Power Requirements
Common to all modelsDC12V
External Size(W*D*H)
Common to all models200*170*64mm
Package Size(W*D*H)
Common to all models600*430*130mm
Net Weight
Common to all models550g
Gross Weight2.5kg2.5kg2.3kg