| Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ; · SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source · Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ; · SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source; · Haze(ASTM D1003), · Conforms to CIE No.15 , GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 |
|---|
| Application | It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control. |
|---|
| Integrating Sphere Size | Φ154mm |
|---|
| Light Source | 360 nm to 780 nm, Combined LED Light, 400nm cut-off light source,420nm Cut-off light source, UV Lamp |
|---|
| Spectrophotometric Mode | Concave Grating |
|---|
| Sensor | 256 Image Element Double Array CMOS Image Sensor |
|---|
| Wavelength Range | 360-780nm |
|---|
| Wavelength Interval | 10nm |
|---|
| Semi-band Width | 10nm |
|---|
| Measured Reflectance Range | 0-200% |
|---|
| Measuring Aperture | Reflective: Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; · Transmissive: Φ30mm/Φ25.4mm; |
|---|
| Specular Component | Reflectance: SCI&SCE / Transmittance: SCI&SCE |
|---|
| Color Space | CIE LAB, XYZ, Yxy, LCh, CIE LUV, Musell, s-RGB, HunterLab, βxy, DIN |
|---|
| Color Difference Formula | ΔE * ab, ΔE * uv, ΔE * 94, ΔE * cmc(2:1), ΔE * cmc(1:1) , ΔE * 00 , DINΔE 99 ,ΔE (Hunter), |
|---|
| Other Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter, YI (ASTM D1925, ASTM 313),TI (ASTM E313, CIE/ISO), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, Gardner Index, Pt-Co Index, 555 Index |
|---|
| Observer Angle | 2°/10° |
|---|
| Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 |
|---|
| Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
|---|
| Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
|---|
| Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%) · Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%) · Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
|---|
| Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.12 (Average for 12 BCRA Series II color tiles) |
|---|
| Illuminant Life Span | 5 years, more than 3 million times measurements |
|---|
| Display | 7-inch TFT color LCD, Capacitive Touch Screen |
|---|
| Data Port | USB & Bluetooth |
|---|
| Data Storage | Standard 5000 Pcs, Sample 40000 Pcs (One PCS can include both SCI and SCE) |
|---|
| Language | Chinese, English |
|---|
| Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
|---|
| Storage Environment | -20~50℃, 0~85%RH (no condensing) |
|---|
| Standard Accessory | White and Black Calibration Board, Checking Green Board, Sample Holder, ∮ 4mm, ∮ 8mm, ∮ 15mm, ∮ 25.4mm Aperture, Power Adapter, USB Cable, User Guide, PC Software |
|---|
| Optional Accessory | Micro printer, Transmissive Test Clamp Component |
|---|
| Power S upply | DC 24V, 3A; Power adapter: 110~230V 50/60HZ |
|---|
| E xternal Size(L*W*H) | 370*300*200mm |
|---|
| Weight | 9.6kg |
|---|
| Package Size (W* D*H) | 3 50*470*520mm |
|---|
| Gross Weight | 1 8kg |
|---|