Home/Catalogue/PH-810 / PH-980

Laboratory analysis

Benchtop Dissolved Oxygen Meter

PH-810 / PH-980

Instrumental measurement of physicochemical parameters for laboratory workflows.

Made to orderPrice on request
Manufacturer
BIOBASE
Request a quote
Reply within 24 hoursValidated selection and configurationDelivery across mainland Portugal, Madeira, the Azores, and all European countries.

01 / Key features

Key features

  • Digital measurement
  • Method matched to the parameter
  • Repeatable results and data capture

02 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterPH-810PH-980
DO
Common to all modelsRange · 0.0~20.0mg/L or ppm · 0.0~20.0mg/L or ppm
DO (2)
Common to all modelsAccuracy · ±0.5mg/L · ±0.2mg/L
DO (3)
Common to all modelsResolution · 0.1mg/L · 0.01, 0.1mg/L, selectable
% Saturation
Common to all modelsRange · 0.0~200.0% · 0.0~200.0%
% Saturation (2)
Common to all modelsAccuracy · ±2.0% · ±2.0%
% Saturation (3)
Common to all modelsResolution · 1% · 0.1, 1%, selectable
Temperature — Range
Common to all models0~60°C/32~140°F
Temperature — Accuracy±1°C/±1.8°F±0.5°C/±0.9°F
Temperature — Resolution
Common to all models0.1°C/0.1°F
Temperature — Offset Calibration
Common to all models1 point, reading ±10°C
Other Specifications
Common to all modelsDissolved Oxygen Calibration · 1 or 2 points · 1 or 2 points
Other Specifications (2)
Common to all modelsTemperature Compensation · 0~40°C, automatic · 0~50°C, automatic
Other Specifications (3)
Common to all modelsBarometric Pressure Correction · 60.0~112.5kPa/450~850mmHg, manual · 60.0~112.5kPa/450~850mmHg, manual
Other Specifications (4)
Common to all modelsSalinity Correction · 0.0~35.0g/L, manual · 0.0~50.0g/L, manual
Other Specifications (5)
Common to all modelsStability Criteria · / · Low or high
Other Specifications (6)
Common to all modelsCalibration Due Alarm · / · 1 to 31 days or off
Other Specifications (7)
Common to all modelsHold Function · Manual or auto-endpoint · Manual or auto-endpoint
Other Specifications (8)
Common to all modelsMemory · / · 500 data sets
Other Specifications (9)
Common to all modelsCommunication Interface · / · USB
Other Specifications (10)
Common to all modelsConnector · 6-pin mini-DIN · 6-pin mini-DIN
Other Specifications (11)
Common to all modelsDisplay · Custom LCD(120*60mm) · Custom LCD(125*100mm)
Other Specifications (12)
Common to all modelsPower Requirements · DC9V power adapter · DC5V power adapter
Other Specifications (13)
Common to all modelsDimensions(mm) · 210*205*75mm · 210*188*60mm
Other Specifications (14)
Common to all modelsWeight(kg) · 1.5kg · 1.5kg
Other Specifications (15)
Common to all modelsPackage Size(W*D*H)mm · 310*240*180mm · 310*240*180mm
Other Specifications (16)
Common to all modelsGross Weight(kg) · 1.7kg · 1.7kg

MADE-TO-ORDER SUPPLY

Do you need this equipment?

Share the application, configuration, quantity and delivery location. We prepare a tailored proposal with the required documentation.

Request a quote