01 / Key features

Key features

  • Digital measurement
  • Method matched to the parameter
  • Repeatable results and data capture

02 / LaboratoriX technical datasheet

LaboratoriX technical datasheet

Technical parameters consolidated from the manufacturer documentation. Each column corresponds to one model; shared values are clearly identified. Final configuration, accessories, power supply and applicable documentation are confirmed with the quotation.

ParameterPH-950
Conductivity
Range · Standard · CON-1: 2μs/cm~20000μs/cm
Conductivity (2)
Range · Optional · CON-0.01: 0.01μs/cm~20μs/cm CON-0.1: 0.1μs/cm~200μs/cm CON-10: 100μs/cm~200ms/cm
Conductivity (3)
Accuracy · ±0.5% F.S.
Conductivity (4)
Resolution · 0.001, 0.01, 0.1, 1
Conductivity (5)
Calibration Points · 1 to 5 points
Conductivity (6)
Calibration Solutions · 10μS/cm, 84μS/cm, 1413μS/cm, 12.88mS/cm, 111.8mS/cm
TDS
Range · 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt
TDS (2)
Accuracy · ±1%F.S.
TDS (3)
Resolution · 0.01, 0.1, 1
Salinity
TDS Factor · 0.1~1.0(default 0.5)
Salinity (2)
Range · 0.00~42.00psu, 0.00~80.00ppt
Salinity (3)
Accuracy · ±1%F.S.
Resistivity
Resolution · 0.01, 0.1
Resistivity (2)
Range · 0.00~20.00MΩ
Resistivity (3)
Accuracy · ±1% F.S.
Temperature — Resolution
0.01
Temperature — Range
0~105°C/32~221°F
Temperature — Accuracy
±0.5°C/±0.9°F
Other Specifications
Resolution · 0.1°C/0.1°F
Other Specifications (2)
Offset Calibration · 1 point, reading ±10°C
Other Specifications (3)
Temperature Compensation · 0~100°C, manual or automatic
Other Specifications (4)
Temperature Coefficient · Linear(0.0~10.0%/°C), non-linear, pure water
Other Specifications (5)
Reference Temperature · 20/25°C
Other Specifications (6)
Cell Constant · K=0.1, 1, 10
Other Specifications (7)
Stability Criteria · Low or high
Other Specifications (8)
Calibration Due Alarm · 1 to 31 days or off
Other Specifications (9)
Calibration Factor Display · Yes
Other Specifications (10)
Hold Function · Manual or auto-endpoint
Other Specifications (11)
Memory · 500 data sets
Other Specifications (12)
Communication Interface · USB
Other Specifications (13)
Connector · 6-pin mini-DIN, 3.5mm jack socket
Other Specifications (14)
Display · Custom LCD(125*100mm)
Other Specifications (15)
Power Requirements · DC5V power adapter
Other Specifications (16)
Dimensions(mm) · 210*188*60mm
Other Specifications (17)
Weight(kg) · 1.5kg
Other Specifications (18)
Package Size(W*D*H)mm · 310*240*180mm
Other Specifications (19)
Gross Weight(kg) · 1.7kg